PN2092
Pressure sensor with display
PN-100-SER14-MFRKG/US/ /V
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — PN2092-02 — 01.03.2024 —
Power-on delay time [s]
0.3
Integrated watchdog
yes
Inputs / outputs
Number of inputs and outputs
Number of digital outputs: 2; Number of analogue outputs: 1
Outputs
Total number of outputs
2
Output signal
switching signal; analogue signal; IO-Link; (configurable)
Electrical design
PNP/NPN
Number of digital outputs
2
Output function
normally open / normally closed; (parameterisable)
Max. voltage drop switching
output DC
[V]
2
Permanent current rating of
switching output DC
[mA]
250
Switching frequency DC [Hz]
< 500
Number of analogue outputs
1
Analogue current output [mA]
4...20; (scalable 1:5)
Max. load [Ω]
500
Analogue voltage output [V]
0...10; (scalable 1:5)
Min. load resistance [Ω]
2000
Short-circuit protection
yes
Type of short-circuit
protection
pulsed
Overload protection
yes
Measuring/setting range
Measuring range 0...100 bar 0...1450 psi 0...10 MPa
Analogue start point 0...80 bar 0...1160 psi 0...8 MPa
Analogue end point 20...100 bar 290...1450 psi 2...10 MPa
Factory setting / CMPT = 2
Set point SP 0.6...100 bar 10...1450 psi 0.06...10 MPa
Reset point rP 0.2...99.6 bar 4...1444 psi 0.02...9.96 MPa
Min. difference between SP
and rP
0.6 bar 6 psi 0.06 MPa
In steps of 0.2 bar 2 psi 0.02 MPa
Status_B High Resolution / CMPT = 3
Set point SP 0.6...100 bar 9...1450 psi 0.06...10 MPa
Reset point rP 0.2...99.6 bar 3...1444 psi 0.02...9.96 MPa
Min. difference between SP
and rP
0.5 bar 6 psi 0.05 MPa
In steps of 0.1 bar 1 psi 0.01 MPa
Accuracy / deviations
Switch point accuracy
[% of the span]
< ± 0,4; (Turn down 1:1)
Repeatability [% of the span]
< ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1)
Characteristics deviation
[% of the span]
< ± 0,25 (BFSL) / < ± 0,5 (LS); (Turn down 1:1; BFSL
= Best Fit Straight Line; LS = limit value setting)