PN2092
Pressure sensor with display
PN-100-SER14-MFRKG/US/ /V
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — PN2092-02 — 01.03.2024 —
1 alphanumeric display 4-digit red/green
2 LEDs Display unit / switching status
3 programming button
4 upper part of the housing can be rotated 345°
Product characteristics
Number of inputs and outputs
Number of digital outputs: 2; Number of analogue outputs: 1
Measuring range 0...100 bar 0...1450 psi 0...10 MPa
Process connection
threaded connection G 1/4 internal thread (DIN EN ISO 1179-2)
Application
Special feature
Gold-plated contacts
Measuring element
ceramic-capacitive pressure measuring cell
Application
for industrial applications
Media
Liquids
Conditionally suitable for
use in gases at pressures > 25 bar only on request
Medium temperature [°C]
-25...80
Min. bursting pressure 650 bar 9400 psi 65 MPa
Pressure rating 300 bar 4350 psi 30 MPa
Vacuum resistance -1000 mbar -0.1 MPa
Type of pressure
relative pressure
Electrical data
Operating voltage [V]
18...30 DC; (to SELV/PELV)
Current consumption [mA]
< 35
Min. insulation resistance [MΩ]
100; (500 V DC)
Protection class
III
Reverse polarity protection
yes
PN2092
Pressure sensor with display
PN-100-SER14-MFRKG/US/ /V
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — PN2092-02 — 01.03.2024 —
Power-on delay time [s]
0.3
Integrated watchdog
yes
Inputs / outputs
Number of inputs and outputs
Number of digital outputs: 2; Number of analogue outputs: 1
Outputs
Total number of outputs
2
Output signal
switching signal; analogue signal; IO-Link; (configurable)
Electrical design
PNP/NPN
Number of digital outputs
2
Output function
normally open / normally closed; (parameterisable)
Max. voltage drop switching
output DC
[V]
2
Permanent current rating of
switching output DC
[mA]
250
Switching frequency DC [Hz]
< 500
Number of analogue outputs
1
Analogue current output [mA]
4...20; (scalable 1:5)
Max. load [Ω]
500
Analogue voltage output [V]
0...10; (scalable 1:5)
Min. load resistance [Ω]
2000
Short-circuit protection
yes
Type of short-circuit
protection
pulsed
Overload protection
yes
Measuring/setting range
Measuring range 0...100 bar 0...1450 psi 0...10 MPa
Analogue start point 0...80 bar 0...1160 psi 0...8 MPa
Analogue end point 20...100 bar 290...1450 psi 2...10 MPa
Factory setting / CMPT = 2
Set point SP 0.6...100 bar 10...1450 psi 0.06...10 MPa
Reset point rP 0.2...99.6 bar 4...1444 psi 0.02...9.96 MPa
Min. difference between SP
and rP
0.6 bar 6 psi 0.06 MPa
In steps of 0.2 bar 2 psi 0.02 MPa
Status_B High Resolution / CMPT = 3
Set point SP 0.6...100 bar 9...1450 psi 0.06...10 MPa
Reset point rP 0.2...99.6 bar 3...1444 psi 0.02...9.96 MPa
Min. difference between SP
and rP
0.5 bar 6 psi 0.05 MPa
In steps of 0.1 bar 1 psi 0.01 MPa
Accuracy / deviations
Switch point accuracy
[% of the span]
< ± 0,4; (Turn down 1:1)
Repeatability [% of the span]
< ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1)
Characteristics deviation
[% of the span]
< ± 0,25 (BFSL) / < ± 0,5 (LS); (Turn down 1:1; BFSL
= Best Fit Straight Line; LS = limit value setting)
PN2092
Pressure sensor with display
PN-100-SER14-MFRKG/US/ /V
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — PN2092-02 — 01.03.2024 —
Hysteresis deviation
[% of the span]
< ± 0,1; (Turn down 1:1)
Long-term stability
[% of the span]
< ± 0,05; (Turn down 1:1; per 6 months)
Temperature coefficient zero
point
[% of the span / 10 K]
< ± 0,2; (-0...80 °C)
Temperature coefficient span
[% of the span / 10 K]
< ± 0,2; (-0...80 °C)
Notes on the accuracy /
deviation
switch point accuracy, linearity error under DNV GL: < ± 1%: < ± 1%
Response times
Response time [ms]
< 1.5
Delay time programmable dS,
dr
[s]
0...50
Damping process value dAP [s]
0...4
Damping for the analogue
output dAA
[s]
0...4
Max. response time analogue
output
[ms]
3
Software / programming
Parameter setting options
hysteresis / window; normally open / normally closed; switch-on/
switch-off delay; Damping; Display unit; current/voltage output
Interfaces
Communication interface
IO-Link
Transmission type
COM2 (38,4 kBaud)
IO-Link revision
1.1
SDCI standard
IEC 61131-9
SIO mode
yes
Required master port type
A; (when pin 2 not connected: B)
Supported DeviceIDs Type of operation DeviceID
Factory setting / CMPT = 2 461
Status_B High Resolution / CMPT = 3 972
Note For further information please see the IODD PDF file under "Downloads"
Factory setting / CMPT = 2
Profiles Smart Sensor - SSP 0 Generic Profiled Sensor
Function Device identification
Function Process data variable
Function Device diagnosis
Min. process cycle time [ms]
2.3
IO-Link resolution pressure [bar]
0.1
IO-Link process data
(cyclical)
function bit length
pressure 14
binary switching information 2
IO-Link functions (acyclical)
application specific tag
PN2092
Pressure sensor with display
PN-100-SER14-MFRKG/US/ /V
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — PN2092-02 — 01.03.2024 —
Status_B High Resolution / CMPT = 3
Profiles Smart Sensor - SSP 3.1 Measuring Sensor
Common - I&D Identification and Diagnosis
Min. process cycle time [ms]
3
IO-Link resolution pressure [bar]
0.05
IO-Link process data
(cyclical)
function bit length
pressure 16
device status 4
binary switching information 2
IO-Link functions (acyclical)
application specific tag
Operating conditions
Ambient temperature [°C]
-25...80
Storage temperature [°C]
-40...100
Protection
IP 65; IP 67
Tests / approvals
EMC DIN EN 61000-6-2
DIN EN 61000-6-3
Shock resistance DIN EN 60068-2-27 50 g (11 ms)
Vibration resistance DIN EN 60068-2-6 20 g (10...2000 Hz)
MTTF [years]
138
UL approval UL approval no. J013
Pressure Equipment Directive
Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Mechanical data
Weight [g]
275
Housing
cylindrical
Dimensions [mm]
Ø 34 / L = 90.7
Materials
stainless steel (316L/1.4404); PBT+PC-GF30; PBT-GF20; PC
Materials (wetted parts)
stainless steel (316L/1.4404); Al2O3 (ceramics); FKM
Min. pressure cycles
100 million
Tightening torque [Nm]
25...35; (recommended tightening torque; depends
on the lubrication, the seal and the pressure load)
Process connection
threaded connection G 1/4 internal thread (DIN EN ISO 1179-2)
Restrictor element integrated
no (can be retrofitted)
Displays / operating elements
Display Display unit 3 x LED, green (bar, psi, MPa)
switching status 2 x LED, yellow
measured values alphanumeric display, red/green 4-digit
Remarks
Pack quantity
1 pcs.
PN2092
Pressure sensor with display
PN-100-SER14-MFRKG/US/ /V
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — PN2092-02 — 01.03.2024 —
Electrical connection
Connector: 1 x M12; coding: A; Contacts: gold-plated
Connection
OUT1 switching output
OUT2 switching output
analogue output
Core colours :
BK = black
BN = brown
BU = blue
WH = white